Cookie Consent by Free Privacy Policy Generator PS1440 Laboratory Power Supply - 0-60V, 0-24A
Udskriv produktside

Joy-It - PS1440 Laboratory Power Supply - 0-60V, 0-24A

Produktnr.: H63815  |  Producentvarekode: JT-PS1440-C
NEW
2,845.00 DKK incl. VAT
2,276.00 DKK excl. VAT

Order qty.


Central warehouse, Struer:
On remote storage. Delivery 9-10 days.
Lager i Kbh. butik:
Ikke på lager. Klik & Hent om 9-10 days.

Cheapest shipping: Kr. 0,-
Click & Collect (in store): Kr. 0,-
You must have a user account and be logged in to use this feature. For account creation Click here.
Click here for a quote by min. stk.

With our PS1440-C you get a programmable laboratory power supply, which provides you with DC voltages between 0.01 to 60 V and DC currents between 0.01 to 24 A at the voltage output.

With the help of the intuitive control panel up to 9 different DC voltages can be programmed, stored and recalled, even individual settings of various protection and limiting functions ( e.g. overvoltage protection ) are programmable.

The corresponding values can be set very conveniently via the keypad and / or the rotary control and are clearly displayed thanks to the high-resolution 2.4“ color display.

Features:

  • Complete device ready for immediate use
  • Battery charging function
  • Values can be entered conveniently via keypad
  • Over current & over voltage protection adjustable
  • Integrated RTC
  • NTC temperature sensor
  • Included detailed
  • Documentation in English, German & French

Specifications:

  • Input voltage: 230 V
  • Output voltage: 0 - 60 V
  • Output current: 0 - 24 A
  • Output power: 0 - 1440 W
  • Input voltage accuracy: ± 1 % + 5 digits
  • Output voltage accuracy: ± 0,3 % + 3 digits
  • Output current accuracy: ± 0,5 % + 5 digits
  • Battery voltage: ± 0,5 % + 3 digits
  • Input voltage measurement resolution: 0,01 V
  • Output voltage measurement resolution: 0,01 V
  • Current measurement resolution: 0,01 V
  • Battery voltage measurement resolution: 0,01 V
  • Response time in constant voltage mode: 2 ms @ 0,1 - 5 A
  • Load regulation in constant voltage mode: ± 0,1 % + 2 digits
  • Load regulation in constant current mode: ± 0,1 % + 3 digits
  • Measuring range electric charge: 0 - 9999,99 Ah
  • Measuring range energy: 0 - 9999,99 Wh
  • Statistical errors in electric charge & energy: ± 2 %
  • Output ripple:
    • 100 mV VPP @ 12 A,
    • 150 mV VPP @ 24 A
  • Sensor temperature detection range: -10 - 100 °C / 0 - 200 °F
  • Sensor temperature detection accuracy: ± 3 °C / ± 6 °F
  • Working mode: Step-down operation
  • Screen brightness setting: Level 0 - 5, 6 levels in total
  • Permissible working temperature: -10 - 40 °C / 0 - 104 °F

Properties