Features:
- Constant voltage + constant current mode output
- Metal housing design with functional ground
- Built-in active PFC function
- Class 2 power unit
- No load / standby power consumption < 0.5W
- IP65 rating for indoor or outdoor installations
- Function options: Io and Vo adjustable through built-in potentiometer
- Typical lifetime > 50.000 hours
- 5 years warranty
- for professional use only - This device must be installed by a qualified person.
Specifications:
- Output:
- DC voltage: 24 V
- Constant current region : 12 V - 24 V
- Rated current: 4 A
- Rated power: 96 W (200 VAC to 305 VAC), 70 W (100 VAC to 180 VAC)
- Ripple & noise (max.): 200 mVp-p
- Voltage adj. range: 21.6 V - 26.4 V
- Current adj. range: 2 A - 4 A
- Voltage tolerance: ± 3.0 %
- Line regulation: ± 0.5 %
- Load regulation: ± 1.0 %
- Setup, rise time : 1000 ms, 80 ms / 115 VAC, 500 ms, 100ms / 230 VAC
- Hold-up time (typ.): 15 ms / 230 VAC, 10 ms / 115 VAC (at full load)
- Input:
- Voltage range: 100-305 VAC 142-431 VDC
- Frequency range: 47 to 63 Hz
- Power factor: PF = 0.97 / 115 VAC, PF = 0.95 / 230 VAC, PF = 0.92 / 227 VAC at full load
- Total harmonic distortion: THD <20% (@load = 50% / 115 VAC, @load = 60% / 230 VAC; @load = 75% / 277 VAC)
- Efficiency (typ.): 88 %
- AC current: 1.1 A / 115 VAC, 0.6 A / 230 VAC, 0.5 A / 227 VAC
- Inrush current (typ.): Cold start 60 A / 230 VAC
- Max. PSUs on 16A circuit braker: 3 units (circuit braker type B) / 6 units (circuit braker type C) at 230 VAC
- Leakage current: < 0.75 mA / 277 VAC
- No load / standby power consumption: <0.5 W
- Protection:
- Overcurrent :
- 95 to 108 %
- Protection type: Constant current limiting, recovers automatically after fault condition is removed
- Short-circuit: Hiccup mode, recovers automatically after fault condition is removed
- Overvoltage:
- 28 V - 34 V
- Protection type: Shut down output voltage, re-power on to recover
- Overtemperature: Shut down output voltage, re-power on to recover
- Environment:
- Working temperature: -40 °C to +90 °C
- Max. case temperature: +90 °C
- Working humidity: 20 - 95% RH non-condensing
- Storage temperature, humidity: -40 °C - +80 °C, 10 - 95 % RH
- Temperature coefficient: ± 0.03 % / °C (0 °C to 60 °C)
- Vibration: 10 to 500 Hz, 5 G 12 min. / 1 cycle, period for 72 min. each along X, Y, Z axes
- Safety & EMC:
- Safety standards: UL8750 (type "HL"), CSA C22.2 no. 250.13-12; ENEC EN61347-1, EN61347-2-13 independent, EN62384; GB19510.14,GB19510.1; IP65 approved
- Withstand voltage: I/P-O/P: 3.75K VAC, I/P-FG: 2.0K VAC, O/P-FG: 1.5K VAC
- Isolation resistance: I/P-O/P, I/P-FG, O/P-FG: 100M Ohm / 500 VDC / 25 °C / 70 % RH
- EMC emission: Compliance to EN55015, EN61000-3-2 Class C (@load =50%); EN61000-3-3; GB17625.1,GB17743
- EMC immunity: Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level (surge immunity Line-Earth 6KV, Line-Line 4KV)
- Others:
- MTBF: 978.2K hrs min.; Telcordia SR-332 (Bellcore) ; 282.9Khrs min.; MIL-HDBK-217F (25 °C)
- Dimensions: 199 x 63 x 35.5 mm (L x W x H)
|